Â
Specification | |
Item | UTP CAT6Â cable |
Inner Conductor | 23AWG,0.57mm Bare Copper |
Insulation | 1.02+Â 0.03mm HDPE |
Insulation color | Blue/White-bule Orange/White-orange Green/White-green Brown/White-brown |
Jacket | 6.2+0.2mm PVC / PE Jacket  any color |
Note: Other specifications according to customer requirements!!! |
Electrical Characteristics | |
Impedance: 100+/-15 Ohm | Imbalance of Pair D.C.Resistance ≤2.5% |
Capacitance: ≤ 5.6 pF/M | Insulation Resistance ≥5000 MΩKM |
Conductor D.C.Resistance ≤9.5Ω/100m | Spark test:2KV |
Frequency (MHZ) |
RL (dB) |
Attenuation (dB/100M) |
Next (dB/100M) |
PS NEXT (dB/100M) |
ELFEXT (dB/100M) |
PS ELFEXT (dB/100M) |
0.772 | 19.4 | 1.8 | 76 | 74.0 | 70.0 | 67.0 |
1.00 | 20.0 | 2.0 | 74.3 | 72.3 | 67.8 | 64.8 |
4.00 | 23.0 | 3.8 | 65.3 | 63.3 | 55.8 | 52.8 |
8.00 | 24.5 | 5.3 | 60.8 | 58.8 | 49.7 | 46.7 |
10.00 | 25.0 | 6..0 | 59.3 | 57.3 | 47.8 | 44.8 |
16.00 | 25.0 | 7.6 | 56.2 | 54.2 | 43.7 | 40.7 |
20.00 | 25.0 | 8.5 | 54.8 | 52.8 | 41.8 | 38.8 |
25.00 | 24.3 | 9.5 | 53.3 | 51.3 | 39.8 | 36.8 |
31.25 | 23.6 | 10.7 | 51.9 | 49.9 | 37.9 | 34.9 |
62.5 | 21.5 | 15.4 | 47.4 | 45.4 | 31.8 | 28.9 |
100.00 | 20.1 | 19.8 | 44.3 | 42.3 | 27.9 | 24.8 |
Use Range :
A Local Area Network or LAN cable now connects a massive number of personal computers, printers, file servers, and workstations in the modem office of business and manufacturing facilities. Local Area Networks such as token-ring networks or Ethernet are commonly connected by means of hubs.Â
LAN cables are relatively easy and simple to handle, install, use, and terminate. It is capable of performing efficiently and transmits the data accurately between the communication devices.
Here is some of our network cable pictures as follow:

if you have any inquiry, please contact with us!!!

 UTP CAT6 cable Construction:

Â
Specification | |
Item | UTP CAT6Â cable |
Inner Conductor | 23AWG,0.57mm Bare Copper |
Insulation | 1.02+Â 0.03mm HDPE |
Insulation color | Blue/White-bule Orange/White-orange Green/White-green Brown/White-brown |
Jacket | 6.2+0.2mm PVC / PE Jacket  any color |
Note: Other specifications according to customer requirements!!! |
Electrical Characteristics | |
Impedance: 100+/-15 Ohm | Imbalance of Pair D.C.Resistance ≤2.5% |
Capacitance: ≤ 5.6 pF/M | Insulation Resistance ≥5000 MΩKM |
Conductor D.C.Resistance ≤9.5Ω/100m | Spark test:2KV |
Frequency (MHZ) |
RL (dB) |
Attenuation (dB/100M) |
Next (dB/100M) |
PS NEXT (dB/100M) |
ELFEXT (dB/100M) |
PS ELFEXT (dB/100M) |
0.772 | 19.4 | 1.8 | 76 | 74.0 | 70.0 | 67.0 |
1.00 | 20.0 | 2.0 | 74.3 | 72.3 | 67.8 | 64.8 |
4.00 | 23.0 | 3.8 | 65.3 | 63.3 | 55.8 | 52.8 |
8.00 | 24.5 | 5.3 | 60.8 | 58.8 | 49.7 | 46.7 |
10.00 | 25.0 | 6..0 | 59.3 | 57.3 | 47.8 | 44.8 |
16.00 | 25.0 | 7.6 | 56.2 | 54.2 | 43.7 | 40.7 |
20.00 | 25.0 | 8.5 | 54.8 | 52.8 | 41.8 | 38.8 |
25.00 | 24.3 | 9.5 | 53.3 | 51.3 | 39.8 | 36.8 |
31.25 | 23.6 | 10.7 | 51.9 | 49.9 | 37.9 | 34.9 |
62.5 | 21.5 | 15.4 | 47.4 | 45.4 | 31.8 | 28.9 |
100.00 | 20.1 | 19.8 | 44.3 | 42.3 | 27.9 | 24.8 |
Use Range :
A Local Area Network or LAN cable now connects a massive number of personal computers, printers, file servers, and workstations in the modem office of business and manufacturing facilities. Local Area Networks such as token-ring networks or Ethernet are commonly connected by means of hubs.Â
LAN cables are relatively easy and simple to handle, install, use, and terminate. It is capable of performing efficiently and transmits the data accurately between the communication devices.
Here is some of our network cable pictures as follow:

if you have any inquiry, please contact with us!!!

Â
The lithium Battery Protection Board is the charge and discharge protection for the series-connected lithium battery pack; when fully charged, it can ensure that the voltage difference between the individual cells is less than the set value (generally ±20mV), so as to realize the equal charge of each single cell of the battery pack. , effectively improving the charging effect in the series charging mode; at the same time, it detects the overvoltage, undervoltage, overcurrent, short circuit, and overtemperature status of each single cell in the battery pack to protect and prolong the battery life; undervoltage protection makes each A single-cell battery is used to avoid damage to the battery due to overdischarge.
Lithium Iron Battery,Lithium Iron Battery Board,Industrial Control Board,Medical PCBA Board,Circuit Board Assembly
Huizhou Liandajin Electronic Co., Ltd , https://www.ldjcircuitboard.com