When working with inverters, users often encounter a wide range of parameters—sometimes dozens or even hundreds. While many of these can be left at factory settings, some are critical for optimal performance and must be adjusted based on specific applications. Understanding how to configure these parameters is essential for both efficiency and safety.
Each inverter model has its own set of parameters, and the naming conventions can vary significantly. For simplicity, this article uses the basic parameter names from a Fuji inverter as an example, which are commonly found across most inverter types. This allows for a more general understanding without getting lost in brand-specific details.
One of the key parameters is acceleration/deceleration time. The acceleration time refers to how long it takes for the output frequency to rise from 0 to maximum, while deceleration time is the reverse. These settings are crucial because they affect the motor’s ability to handle load changes without triggering overcurrent or overvoltage faults. Properly setting these times ensures smooth operation and prevents unnecessary tripping of the inverter.
The second important parameter is torque boost, also known as torque compensation. This feature helps maintain motor torque at low speeds by increasing the voltage-to-frequency ratio. When set automatically, the inverter adjusts the voltage during acceleration to provide better starting performance. Manual adjustment can offer even more precise control, especially for variable torque loads like fans or pumps.
Electronic thermal overload protection is another vital function that safeguards the motor from overheating. It works by calculating the motor's temperature based on current and frequency. However, this feature is only suitable for one-to-one motor setups. In multi-motor systems, additional thermal relays should be used for each motor.
Frequency limits define the upper and lower bounds of the inverter’s output frequency. This function is useful for protecting the system from unexpected signal faults or mechanical issues. It can also be used to limit speed, such as in conveyor belt systems where running at a lower speed reduces wear and tear.
Bias frequency, or deviation frequency, adjusts the base frequency when using external analog signals. Some inverters allow polarity settings, making it easier to fine-tune the output to match the desired speed. This is particularly useful in applications where precise control is required.
Gain settings for frequency signals help compensate for differences between the external signal and the inverter’s internal reference. By adjusting the gain, users can ensure accurate frequency control, especially when dealing with different input ranges like 0–5V or 0–10V.
Torque limits divide into drive and brake torque settings. These parameters control the motor’s torque during acceleration and deceleration, improving performance under sudden load changes. Setting them appropriately ensures the inverter doesn’t trip due to excessive current or voltage spikes.
Acceleration/deceleration mode selection allows users to choose between linear, nonlinear, or S-shaped curves. Different load types benefit from different curve shapes. For example, fans may perform better with nonlinear curves, while constant torque loads work well with S-shaped curves. Choosing the right curve can prevent trips and improve overall stability.
Torque vector control is a sophisticated method that mimics DC motor performance by separating stator current into magnetic and torque components. This allows for more precise control, especially at low speeds. Most modern inverters use non-feedback vector control, which provides good performance without the need for external feedback devices.
Energy-saving control is ideal for fans and pumps, where torque decreases with the square of the speed. This mode optimizes efficiency by reducing output voltage based on load, leading to significant power savings. However, it should be used carefully, as improper configuration can lead to instability or frequent trips.
It’s worth noting that advanced features like torque vector control and energy-saving modes require careful setup. If not configured properly, they can cause the inverter to trip. Common issues include mismatched motor parameters, incorrect control modes, or improper motor parameter readings. Always refer to the manual and test settings gradually to avoid problems.
By understanding and correctly configuring these parameters, users can maximize the performance, reliability, and lifespan of their inverter systems.