During the maintenance of the high-voltage inverter in summer, pay attention to the temperature of the installation environment of the inverter, and regularly clean the dust inside the inverter to ensure the smoothness of the cooling air passage. Strengthen inspections to improve the surrounding environment of inverters, motors and circuits. Check for tightness, ensure correct and reliable connection of each electrical circuit, and prevent unnecessary downtime accidents.

First, daily inspections need to pay attention to matters

1. Carefully monitor and record the display parameters on the human-machine interface of the inverter, and find that the abnormality should be reflected immediately.

2. Carefully monitor and record the ambient temperature of the inverter room. The ambient temperature should be between -5 °C and 40 °C. The temperature rise of the phase shifting transformer cannot exceed 130 °C

3. When the summer temperature is high, the ventilation and heat dissipation of the inverter installation site should be strengthened. Ensure that the surrounding air does not contain excessive amounts of dust, acids, salts, corrosive and explosive gases

4. Summer is a rainy season, and rainwater should be prevented from entering the inverter (for example, rainwater enters the air outlet)

5. The filter on the inverter door should be cleaned once a week. If the working environment is dusty, the cleaning interval should be shortened according to the actual situation.

6. In the normal operation of the inverter, a standard thickness of A4 paper should be firmly adsorbed on the air inlet of the cabinet door.

7. The frequency conversion room must be kept clean and tidy, and should be cleaned at any time according to the actual situation on site.

8. The ventilation and lighting of the inverter room must be good, and the ventilation and heat dissipation equipment (air conditioner, ventilation fan, etc.) can operate normally.

Second, the project needs to be maintained after the inverter stops

1. Thoroughly clean the inside and outside of the inverter cabinet with a vacuum cleaner with a plastic nozzle to ensure that there is no excessive dust around the equipment.

2. Check the ventilation and lighting equipment of the inverter room to ensure that the ventilation equipment can operate normally.

3. Check the connection between the internal cables of the inverter should be correct and reliable.

4. Check all grounding in the inverter cabinet should be reliable, no rust at the grounding point

5, every six months (inside) should be tightened once again each connection nut of the inverter internal cable

6. The inverter resumes operation after a long time stop. The insulation of the inverter (including the phase shift transformer and the main circuit of the bypass cabinet) should be measured. The 2500V megger should be used. After the test insulation is qualified, the inverter can be started.

7. Check the tightness of all electrical connections, check whether there are abnormal discharge marks in each circuit, whether there are strange smells, discoloration, cracks, damage, etc.

8. After each maintenance of the inverter, carefully check for missing screws and wires to prevent short-circuit accidents caused by small metal objects. In particular, after making major changes to the electrical circuit, ensure that the electrical connection is connected correctly and reliably, and prevent the occurrence of 'reverse power transmission' accidents.

KNBL1-32 Residual Current Circuit Breaker With Over Load Protection

KNBL1-32 TWO FUNCTION : MCB AND RCCB FUNCTIONS

leakage breaker is suitable for the leakage protection of the line of AC 50/60Hz, rated voltage single phase 240V, rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will automatically cut off the power within 0.1s to protect human safety and prevent the accident due to the current leakage.
leakage breaker can protect against overload and short-circuit. It can be used to protect the line from being overloaded and short-circuited as wellas infrequent changeover of the line in normal situation. It complies with standard of IEC/EN61009-1 and GB16917.1.


KNBL1-32 Residual Current Circuit Breaker,Residual Current Circuit Breaker with Over Load Protection 1p,Residual Current Circuit Breaker with Over Load Protection 2p

Wenzhou Korlen Electric Appliances Co., Ltd. , https://www.korlen-electric.com

Posted on